Rated thermal power: 0.35–14 MW; Rated working pressure: 0.7/1.0 MPa; The water temperature: 95/115℃; Return water temperature: 70℃; Water capacity: 1,530–26,000 L; Fuel: Natural gas, diesel oil, LPG, pipeline gas, etc. Condensation heat exchanger can be added at the smoke outlet to decrease the smoke-discharging temperature, absorb the sensible and latent heat in the smoke, and improve the heating efficiency (up to 95%).
1. Adopt the structure of three pass wetback,with corrugated furnace which is with large heating surface.
2. Adopt threaded pipe as the smoke pipe to optimize the heat conductivity with high heating efficiency.
3. The front smoke case is connected with chain type, convenient to open; double layered doors for heat.
4. Adopt advanced controller, with the functions of timing control, automatic working records, leakage checking and alarming ,pressure protection, temperature controlling and water shortage protection etc.
5. Condensation heat exchanger can be added in the smoke outlet to decrease the smoke discharging temperature, absorb the sensible and latent heat in the smoke, improve the heating efficiency(up to 95%)
2. Adopt threaded pipe as the smoke pipe to optimize the heat conductivity with high heating efficiency.
3. The front smoke case is connected with chain type, convenient to open; double layered doors for heat.
4. Adopt advanced controller, with the functions of timing control, automatic working records, leakage checking and alarming ,pressure protection, temperature controlling and water shortage protection etc.
5. Condensation heat exchanger can be added in the smoke outlet to decrease the smoke discharging temperature, absorb the sensible and latent heat in the smoke, improve the heating efficiency(up to 95%)
Technical Parameters
| WNS Horizontal Oil(gas)Fired Pressure Hot Water Boiler | |||||||||||||||
| Model | WNS0.35-0.7-95/70-Y(Q) | WNS0.48-0.7-95/70-Y(Q) | WNS0.7-0.7-95/70-Y(Q) | WNS1.05-1.0-95/70-Y(Q) | WNS1.4-1.0-95/70-Y(Q) | WNS2.1-1.0-115/70-Y(Q) | WNS2.8-1.0-115/70-Y(Q) | WNS3.5-1.0-115/70-Y(Q) | WNS4.2-1.0-115/70-Y(Q) | WNS5.6-1.0-115/70-Y(Q) | WNS7-1.0-115/70-Y(Q) | WNS10.5-1.0-115/70-Y(Q) | WNS14-1.0-115/70-Y(Q) | ||
| Item | Unit | ||||||||||||||
| Rated thermal power | MW | 0.35 | 0.48 | 0.7 | 1.05 | 1.4 | 2.1 | 2.8 | 3.5 | 4.2 | 5.6 | 7 | 10.5 | 14 | |
| The working pressure | Mpa | 0.7 | 0.7 | 0.7 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
| The water temperature | ℃ | 95 | 95 | 95 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | 115 | |
| Return water temperature | ℃ | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | |
| Design the thermal efficiency | % | 93.43 | 93.51 | 92.94 | 93.09 | 93.00 | 93.00 | 94.05 | 94 | 94.06 | 94.15 | 94.02 | 94.1 | 94.12 | |
| Water capacity | L | 1520 | 1760 | 1950 | 2520 | 2930 | 4300 | 5820 | 8000 | 10860 | 13500 | 15500 | 24000 | 26000 | |
| Water outlet | mm | 50 | 65 | 80 | 80 | 100 | 100 | 150 | 150 | 200 | 200 | 200 | 250 | 250 | |
| Feed water inlet | mm | 50 | 65 | 80 | 80 | 100 | 100 | 150 | 150 | 200 | 200 | 200 | 250 | 250 | |
| Drain valve | mm | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50*3 | 50*3 | 50*3 | |
| Chimney | mm | 220 | 220 | 280 | 330 | 330 | 400 | 450 | 500 | 600 | 650 | 750 | 1000 | 1200 | |
| Size | Length | mm | 2450 | 2750 | 3050 | 3200 | 3500 | 3900 | 4350 | 5400 | 5500 | 5900 | 6800 | 8000 | 8400 |
| Width | mm | 1450 | 1450 | 1480 | 1690 | 1690 | 1800 | 2160 | 2240 | 2380 | 2450 | 2700 | 3100 | 3200 | |
| Height | mm | 1800 | 1800 | 1970 | 2270 | 2270 | 2504 | 2578 | 2600 | 2880 | 3050 | 3100 | 3600 | 4200 | |
| Size of base | Length | mm | 2000 | 2200 | 2500 | 2700 | 2950 | 3580 | 3850 | 4960 | 4960 | 5720 | 6400 | 7500 | 8000 |
| Width | mm | 900 | 900 | 900 | 1300 | 1300 | 1400 | 1600 | 1700 | 1800 | 2000 | 2100 | 2300 | 2400 | |
| Fuel consumption | N.G | Nm³/H | 38.24 | 52.4 | 76.89 | 115.16 | 153.69 | 228.44 | 303.96 | 367.8 | 455.88 | 607.3 | 735.3 | 1193.7 | 1452 |
| Light oil | KG/H | 31.56 | 43.28 | 63.56 | 95.18 | 127.07 | 188.45 | 250.79 | 326.6 | 377.46 | 501.5 | 633.2 | 985.1 | 1258 | |
| City gas | Nm³/H | 81.26 | 111.35 | 163.4 | 244.72 | 326.6 | 485.35 | 645.9 | 824 | 968.7 | 1290 | 1630 | 2536 | 3146 | |
| Transport weight | kg | 3000 | 3500 | 4000 | 4600 | 6000 | 7600 | 10000 | 12000 | 15000 | 18600 | 23600 | 34000 | 41000 | |
Company Information
Wilford company is specialized in manufacturing the medium and small sized boilers with high quality to solve the high energy efficiency requirements of customers in industrial and commercial fields for steam and heat sources. We supply the whole solution of boilers and boiler systems, reduce energy consumption, save operating costs for each plant, enhancing the environmental protection requirements. Since 1998, the company are insisted on intelligent and lean production as the leading factor to ensure that each product is super safe and high quality. The fuel, gas and electric heating boilers have high technical content. The company has won many inventions, many high-tech products and new technology and new product awards. We regard the boiler’s efficiency index and extremely low nitrogen emission requirements as the main innovation objectives, Keep unremitting efforts in the environmental protection and energy saving of boilers.