Home » Electric boiler » Electric Heating Pressure Hot Water Boiler
Electric Heating Hot Water Boiler
0.12-0.58MW 0.2-0.7Mpa
Rated thermal power :0.06-0.53MW; Rated working pressure :0.7Mpa; Staturated water temperature :95℃;Return water temperature :70℃; Input Power :60-540KW; Rated voltage :3N AC 50Hz 380V; Industry :Foods, Garment, Taextile, Paper, Brewery, Ricemill, Dairy Products, Laundry, Poultry feed, Package, Plywood, Building material, Chemical, etc.Boiler furnace operates under pressure ,with double control of pressure and temperature ,no hidden trouble of safety .Hot water boiler –advanced touch screen controller, digital control system.
Product Description
1.Hot water boiler with pressure –microcomputer controller, built-in backlight LCD screen display, clearly see operation of the boiler .All operations are easily accomplished by simply buttons.
2.High-power heating boiler uses step by step control heating group-it could start or stop working according to load change and significantly reduce the impact to the grid.The boiler could also manually open/stop heating section numbers, which convenient for adjusting boiler electrical heating power.
3.The system controls circulating pump base on boiler water temperature .Hot water boiler –during heating usage ,the circulation pump starts once boiler water reaches the upper limit and stops once boiler water lower than fixed lower limit .Hot water boiler –during bath usage ,the circulation pump stops once boiler water reaches the upper limit and starts once boiler water lower than fixed lower limit.
4.Hot water boiler used for bath/living –inner part already been anticorrosive treated.Furnace body is not easily rusted &corrosion,long life usage and output hot water clean & sanitary .Using advanced centrifugal glass cotton fibre multilayer insulation, less heat loss,energy saving .Famous white color plate exquisite packaging, beautiful and corrosion resistance.
5.Hot water boiler –electric leakage protection , prevent dry burning/ low water level protection, furnace overheating protection, temperature sensor protection, power supply &voltage protection , heating component failure protection etc.
2.High-power heating boiler uses step by step control heating group-it could start or stop working according to load change and significantly reduce the impact to the grid.The boiler could also manually open/stop heating section numbers, which convenient for adjusting boiler electrical heating power.
3.The system controls circulating pump base on boiler water temperature .Hot water boiler –during heating usage ,the circulation pump starts once boiler water reaches the upper limit and stops once boiler water lower than fixed lower limit .Hot water boiler –during bath usage ,the circulation pump stops once boiler water reaches the upper limit and starts once boiler water lower than fixed lower limit.
4.Hot water boiler used for bath/living –inner part already been anticorrosive treated.Furnace body is not easily rusted &corrosion,long life usage and output hot water clean & sanitary .Using advanced centrifugal glass cotton fibre multilayer insulation, less heat loss,energy saving .Famous white color plate exquisite packaging, beautiful and corrosion resistance.
5.Hot water boiler –electric leakage protection , prevent dry burning/ low water level protection, furnace overheating protection, temperature sensor protection, power supply &voltage protection , heating component failure protection etc.
Product system Drawings
Product Detail Analysis
Technical Parameters
LDR Electric Heating Pressure Hot Water Boiler | |||||||||
Type | LDR0.06-0.7-95/70 | LDR0.09-0.7-95/70 | LDR0.12-0.7-95/70 | LDR0.18-0.7-95/70 | LDR0.23-0.7-95/70 | LDR0.35-0.7-95/70 | LDR0.47-0.7-95/70 | LDR0.53-0.7-95/70 | |
Project | Unit | ||||||||
Rated working pressure | MPa | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 |
Staturated water temperature/Reture water temperature | ℃ | 95/70 | 95/70 | 95/70 | 95/70 | 95/70 | 95/70 | 95/70 | 95/70 |
Input Power | KW | 60 | 90 | 120 | 180 | 240 | 360 | 480 | 540 |
Input current | A | 90 | 135 | 180 | 270 | 360 | 540 | 720 | 810 |
Rated voltage | V | 3N AC 50Hz 380V | |||||||
Power×Group | KW×P | 15×4 | 15×6 | 15×8 | 25×6+15×2 | 25×9+15 | 36×10 | 36×12+25×2 | 36×15 |
aWater outlet diameter | DN | 50 | 50 | 50 | 50 | 50 | 80 | 80 | 80 |
b Water return diameter | DN | 50 | 50 | 50 | 50 | 50 | 80 | 80 | 80 |
c Water inlet diameter | DN | 15 | 15 | 15 | 15 | 15 | 25 | 25 | 25 |
d Blowoff Valve diameter | DN | 25 | 25 | 25 | 40 | 40 | 40 | 40 | 40 |
e Safety valve diameter | DN | 15 | 15 | 15 | 25 | 25 | 40 | 40 | 40 |
Overall size | L mm | 750 | 750 | 750 | 1200 | 1200 | 1600 | 1600 | 1600 |
W mm | 650 | 650 | 650 | 1100 | 1100 | 1200 | 1350 | 1350 | |
H mm | 1380 | 1380 | 1380 | 1900 | 1900 | 2000 | 2200 | 2200 | |
LDR0.53 and more ,the structure is seperated,with indepedent control cabinet. | A mm | – | – | – | – | – | 1200 | ||
B mm | – | – | – | – | – | 600 | |||
C mm | – | – | – | – | – | 1800 | |||
Weight | kg | 180 | 200 | 235 | 485 | 525 | 620 | 710 | 820/1350 |
(Following are National inspection-free hot water boiler with pressure ( tap water pressure only ) |
Company Information
Wilford company is specialized in manufacturing the medium and small sized boilers with high quality to solve the high energy efficiency requirements of customers in industrial and commercial fields for steam and heat sources. We supply the whole solution of boilers and boiler systems, reduce energy consumption, save operating costs for each plant, enhancing the environmental protection requirements.
Since 1998, the company are insisted on intelligent and lean production as the leading factor to ensure that each product is super safe and high quality. The fuel, gas and electric heating boilers have high technical content. The company has won many inventions, many high-tech products and new technology and new product awards. We regard the boiler’s efficiency index and extremely low nitrogen emission requirements as the main innovation objectives, Keep unremitting efforts in the environmental protection and energy saving of boilers.
Request A Free Quote
Fill out my online form.
- No5,Nanyuan Road Economic Development Zone, Zhangjiagang
- +86-512-5679 1900
- +86-512-5869 8850
- [email protected]
- +86 17701567985
Agent:
WILFORD SOLE AGENCY IN MEXICO AND CENTRAL AMERICA:
- HM TECNOLOGIA SA DE CV
- Address:9na Calle Poniente y 4ta Ave. Norte # 2-14C, Santa Tecla, La Libertad EI Salvador
- +86-512-5869 8850
- Tel: (503) 22873333
- Contactor: Mr Melendez