Home » CLHS Series Oil(Gas)Fired Hot Water Boiler
CLHS Series Oil(Gas)Fired Hot Water Boiler
Fill out my online form.
Product Description
Rated thermal power: 0.06–0.58 MW; Rated working pressure: Ordinary pressure; Total heating capacity: 50,000–500,000 kcal; Return water temperature: 70℃; Fuel: Natural gas, diesel oil, LPG, pipeline gas, etc. CLHS series hot-water boiler is a three-pass all-wet-back shell-type structure. Main body includes boiler shell, furnace, boiler smoke chamber, and convection bank. Convection smoke tube is made with threaded pipes to enhance heat transfer. Large furnace, high radiation area, three-return design, full-air combustion, good utilization of heating surface.
1.CLHS series hot-water boiler is a three-pass all-wet-back shell-type structure. Main body includes boiler shell, furnace, boiler smoke chamber, and convection bank. Convection smoke tube is made with threaded pipes to enhance heat transfer.
2.Large furnace, high radiation area, three-return design, full-air combustion, good utilization of heating surface. Smoke tubes add disturbance fins inside, increasing heating area, self-cleaning for dust, and improving heat-transfer effectiveness. Using high thermal-resistance insulation materials – minimizing boiler heat losses.
3.More than 90% thermal efficiency. Intelligent, fully automatic control, over-temperature standby. Anti-freezing in cold winter nights, automatic adjustment of heating supply temperature based on outdoor temperature, which maximizes energy saving.
4.Imported burner, pressure spray, complete burning, low noise. Reduced combustion intensity, decreased dust emissions, and minimized output of harmful gases such as NOx – meeting strict environmental requirements.
5.Pressure-connecting structure, safe, reliable, long service life. Multiple chain protections and self-tests such as over-temperature, water shortage, overload, ignition failure, abnormal flame-out, and gas leakage. Expansion water tank directly connects to atmosphere, with no potential safety hazards under atmospheric-pressure operation.
2.Large furnace, high radiation area, three-return design, full-air combustion, good utilization of heating surface. Smoke tubes add disturbance fins inside, increasing heating area, self-cleaning for dust, and improving heat-transfer effectiveness. Using high thermal-resistance insulation materials – minimizing boiler heat losses.
3.More than 90% thermal efficiency. Intelligent, fully automatic control, over-temperature standby. Anti-freezing in cold winter nights, automatic adjustment of heating supply temperature based on outdoor temperature, which maximizes energy saving.
4.Imported burner, pressure spray, complete burning, low noise. Reduced combustion intensity, decreased dust emissions, and minimized output of harmful gases such as NOx – meeting strict environmental requirements.
5.Pressure-connecting structure, safe, reliable, long service life. Multiple chain protections and self-tests such as over-temperature, water shortage, overload, ignition failure, abnormal flame-out, and gas leakage. Expansion water tank directly connects to atmosphere, with no potential safety hazards under atmospheric-pressure operation.
Technical Parameters
| CLHS Vertical Oil(gas)Fired Hot Water Boiler | |||||||||
| Type | CLHS0.06-95/70-Y.Q | CLHS0.12-95/70-Y.Q | CLHS0.17-95/70-Y.Q | CLHS0.23-95/70-Y.Q | CLHS0.35-95/70-Y.Q | CLHS0.47-95/70-Y.Q | CLHS0.58-95/70-Y.Q | ||
| Project | Unit | ||||||||
| Rated thermal power | MW | 0.06 | 0.12 | 0.17 | 0.23 | 0.35 | 0.47 | 0.58 | |
| Total heat capacity | 104kcal | 5 | 10 | 15 | 20 | 30 | 40 | 50 | |
| Rated working pressure | MPa | Ordinary pressure | |||||||
| Fuel consumption | Light diesel oil | kg/h | 5.4 | 10.8 | 16.2 | 21.6 | 32.5 | 43.2 | 54 |
| Natural gas | Nm3/h | 5.8 | 11.7 | 17.5 | 23.4 | 35 | 46.8 | 58.5 | |
| LPG | Nm3/h | 2.5 | 5 | 7.5 | 10 | 15 | 20 | 25 | |
| City gas | Nm3/h | 14.2 | 28.3 | 42.5 | 56.6 | 85 | 113.2 | 141.5 | |
| Water inlet diameter | DN | 50 | 65 | 65 | 65 | 65 | 80 | 100 | |
| Water outlet diameter | DN | 50 | 65 | 65 | 65 | 65 | 80 | 100 | |
| Blowoff valve diameter | DN | 25 | 25 | 25 | 25 | 25 | 40 | 40 | |
| Voltage | V | 220 | 220 | 220 | 220 | 380 | 380 | 380 | |
| Overall size | Length | mm | 800 | 980 | 1150 | 1250 | 1500 | 1550 | 1600 |
| Width | mm | 700 | 850 | 900 | 1000 | 1200 | 1250 | 1450 | |
| Height | mm | 1300 | 1650 | 1800 | 1950 | 2000 | 2100 | 2500 | |
| Weight | kg | 270 | 410 | 450 | 520 | 830 | 980 | 1500 | |
| According to customer order requirements,the company can provide customized products for specific power supply in the world. | |||||||||
Company Information
Wilford company is specialized in manufacturing the medium and small sized boilers with high quality to solve the high energy efficiency requirements of customers in industrial and commercial fields for steam and heat sources. We supply the whole solution of boilers and boiler systems, reduce energy consumption, save operating costs for each plant, enhancing the environmental protection requirements. Since 1998, the company are insisted on intelligent and lean production as the leading factor to ensure that each product is super safe and high quality. The fuel, gas and electric heating boilers have high technical content. The company has won many inventions, many high-tech products and new technology and new product awards. We regard the boiler’s efficiency index and extremely low nitrogen emission requirements as the main innovation objectives, Keep unremitting efforts in the environmental protection and energy saving of boilers.